Description (CNA)
Without quotation marks, any whitespace in the file path for Rockwell Automation FactoryTalk Activation version 4.00.02 remains ambiguous, which may allow an attacker to link to or run a malicious executable. This may allow an authorized, but not privileged local user to execute arbitrary code with elevated privileges on the system. CVSS v3 base score: 8.8, CVSS vector string: (AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H). Rockwell Automation has released a new version of FactoryTalk Activation, Version 4.01, which addresses the identified vulnerability. Rockwell Automation recommends upgrading to the latest version of FactoryTalk Activation, Version 4.01 or later.
Affected (CNA)
| Vendor / product | Versions |
|---|---|
| Rockwell Automation / FactoryTalk Activation | affected FactoryTalk Activation Service, Version 4.00.02 and prior versions. |
CWE
CWE-428
References
- http://www.securityfocus.com/bid/96996
- https://rockwellautomation.custhelp.com/app/answers/detail/a_id/939382
- https://ics-cert.us-cert.gov/advisories/ICSA-17-047-02
ADP enrichment
No English description supplied.