Description (CNA)
Philips e-Alert Unit (non-medical device), Version R2.1 and prior. The software contains hard-coded cryptographic key, which it uses for encryption of internal data.
Affected (CNA)
| Vendor / product | Versions |
|---|---|
| Philips / e-Alert Unit (non-medical device) | affected R2.1 and prior |
CWE
No CWE identifiers supplied.
References
- https://www.usa.philips.com/healthcare/about/customer-support/product-security
- http://www.securityfocus.com/bid/105194
- https://ics-cert.us-cert.gov/advisories/ICSA-18-242-01
ADP enrichment
No English description supplied.