Description (CNA)
A vulnerability has been identified in Opcenter Execution Discrete (All versions < V3.2), Opcenter Execution Foundation (All versions < V3.2), Opcenter Execution Process (All versions < V3.2), Opcenter Intelligence (All versions < V3.3), Opcenter Quality (All versions < V11.3), Opcenter RD&L (V8.0), SIMATIC IT LMS (All versions < V2.6), SIMATIC IT Production Suite (All versions < V8.0), SIMATIC Notifier Server for Windows (All versions), SIMATIC PCS neo (All versions < V3.0 SP1), SIMATIC STEP 7 (TIA Portal) V15 (All versions < V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions < V16 Update 2), SIMOCODE ES V15.1 (All versions < V15.1 Update 4), SIMOCODE ES V16 (All versions < V16 Update 1), Soft Starter ES V15.1 (All versions < V15.1 Update 3), Soft Starter ES V16 (All versions < V16 Update 1). Sending a specially crafted packet to the affected service could cause a partial remote denial-of-service, that would cause the service to restart itself.
Affected (CNA)
| Vendor / product | Versions |
|---|---|
| Siemens / Opcenter Execution Discrete | affected All versions < V3.2 |
| Siemens / Opcenter Execution Foundation | affected All versions < V3.2 |
| Siemens / Opcenter Execution Process | affected All versions < V3.2 |
| Siemens / Opcenter Intelligence | affected All versions < V3.3 |
| Siemens / Opcenter Quality | affected All versions < V11.3 |
| Siemens / Opcenter RD&L | affected V8.0 |
| Siemens / SIMATIC IT LMS | affected All versions < V2.6 |
| Siemens / SIMATIC IT Production Suite | affected All versions < V8.0 |
| Siemens / SIMATIC Notifier Server for Windows | affected All versions |
| Siemens / SIMATIC PCS neo | affected All versions < V3.0 SP1 |
| Siemens / SIMATIC STEP 7 (TIA Portal) V15 | affected All versions < V15.1 Update 5 |
| Siemens / SIMATIC STEP 7 (TIA Portal) V16 | affected All versions < V16 Update 2 |
| Siemens / SIMOCODE ES V15.1 | affected All versions < V15.1 Update 4 |
| Siemens / SIMOCODE ES V16 | affected All versions < V16 Update 1 |
| Siemens / Soft Starter ES V15.1 | affected All versions < V15.1 Update 3 |
| Siemens / Soft Starter ES V16 | affected All versions < V16 Update 1 |
CWE
CWE-20
References
ADP enrichment
No English description supplied.