Description (CNA)
Improper Initialization vulnerability in ABB Relion protection relays - 611 series, ABB Relion protection relays - 615 series IEC 4.0 FP1, ABB Relion protection relays - 615 series CN 4.0 FP1, ABB Relion protection relays - 615 series IEC 5.0, ABB Relion protection relays - 615 series IEC 5.0 FP1, ABB Relion protection relays - 620 series IEC/CN 2.0, ABB Relion protection relays - 620 series IEC/CN 2.0 FP1, ABB Relion protection relays - REX640 PCL1, ABB Relion protection relays - REX640 PCL2, ABB Relion protection relays - REX640 PCL3, ABB Relion protection relays - RER615, ABB Remote Monitoring and Control - REC615, ABB Merging Unit- SMU615 allows Communication Channel Manipulation.This issue affects Relion protection relays - 611 series: from 1.0.0 before 2.0.3; Relion protection relays - 615 series IEC 4.0 FP1: from 4.1.0 before 4.1.9; Relion protection relays - 615 series CN 4.0 FP1: from 4.1.0 before 4.1.8; Relion protection relays - 615 series IEC 5.0: from 5.0.0 before 5.0.12; Relion protection relays - 615 series IEC 5.0 FP1: from 5.1.0 before 5.1.20; Relion protection relays - 620 series IEC/CN 2.0: from 2.0.0 before 2.0.11; Relion protection relays - 620 series IEC/CN 2.0 FP1: from 2.1.0 before 2.1.15; Relion protection relays - REX640 PCL1: from 1.0.0 before 1.0.8; Relion protection relays - REX640 PCL2: from 1.1.0 before 1.1.4; Relion protection relays - REX640 PCL3: from 1.2.0 before 1.2.1; Relion protection relays - RER615: from 2.0.0 before 2.0.3; Remote Monitoring and Control - REC615: from 1.0.0 before 2.0.3; Merging Unit- SMU615: from 1.0.0 before 1.0.2.
Affected (CNA)
| Vendor / product | Versions |
|---|---|
| ABB / Relion protection relays - 611 series | affected 1.0.0 before 2.0.3 |
| ABB / Relion protection relays - 615 series IEC 4.0 FP1 | affected 4.1.0 before 4.1.9 |
| ABB / Relion protection relays - 615 series CN 4.0 FP1 | affected 4.1.0 before 4.1.8 |
| ABB / Relion protection relays - 615 series IEC 5.0 | affected 5.0.0 before 5.0.12 |
| ABB / Relion protection relays - 615 series IEC 5.0 FP1 | affected 5.1.0 before 5.1.20 |
| ABB / Relion protection relays - 620 series IEC/CN 2.0 | affected 2.0.0 before 2.0.11 |
| ABB / Relion protection relays - 620 series IEC/CN 2.0 FP1 | affected 2.1.0 before 2.1.15 |
| ABB / Relion protection relays - REX640 PCL1 | affected 1.0.0 before 1.0.8 |
| ABB / Relion protection relays - REX640 PCL2 | affected 1.1.0 before 1.1.4 |
| ABB / Relion protection relays - REX640 PCL3 | affected 1.2.0 before 1.2.1 |
| ABB / Relion protection relays - RER615 | affected 2.0.0 before 2.0.3 |
| ABB / Remote Monitoring and Control - REC615 | affected 1.0.0 before 2.0.3 |
| ABB / Merging Unit- SMU615 | affected 1.0.0 before 1.0.2 |
CWE
CWE-665
References
ADP enrichment
No English description supplied.
No English description supplied.