← CVE Intelligence

CVE-2022-45044

Siemens / SIPROTEC 5 6MD84 (CP300) PUBLISHED

Description (CNA)

A vulnerability has been identified in SIPROTEC 5 6MD84 (CP300) (All versions < V9.50), SIPROTEC 5 6MD85 (CP200) (All versions), SIPROTEC 5 6MD85 (CP300) (All versions < V9.50), SIPROTEC 5 6MD86 (CP200) (All versions), SIPROTEC 5 6MD86 (CP300) (All versions < V9.50), SIPROTEC 5 6MD89 (CP300) (All versions < V9.64), SIPROTEC 5 6MU85 (CP300) (All versions < V9.50), SIPROTEC 5 7KE85 (CP200) (All versions), SIPROTEC 5 7KE85 (CP300) (All versions < V9.64), SIPROTEC 5 7SA82 (CP100) (All versions < V8.90), SIPROTEC 5 7SA82 (CP150) (All versions < V9.50), SIPROTEC 5 7SA84 (CP200) (All versions), SIPROTEC 5 7SA86 (CP200) (All versions), SIPROTEC 5 7SA86 (CP300) (All versions < V9.50), SIPROTEC 5 7SA87 (CP200) (All versions), SIPROTEC 5 7SA87 (CP300) (All versions < V9.50), SIPROTEC 5 7SD82 (CP100) (All versions < V8.90), SIPROTEC 5 7SD82 (CP150) (All versions < V9.50), SIPROTEC 5 7SD84 (CP200) (All versions), SIPROTEC 5 7SD86 (CP200) (All versions), SIPROTEC 5 7SD86 (CP300) (All versions < V9.50), SIPROTEC 5 7SD87 (CP200) (All versions), SIPROTEC 5 7SD87 (CP300) (All versions < V9.50), SIPROTEC 5 7SJ81 (CP100) (All versions < V8.89), SIPROTEC 5 7SJ81 (CP150) (All versions < V9.50), SIPROTEC 5 7SJ82 (CP100) (All versions < V8.89), SIPROTEC 5 7SJ82 (CP150) (All versions < V9.50), SIPROTEC 5 7SJ85 (CP200) (All versions), SIPROTEC 5 7SJ85 (CP300) (All versions < V9.50), SIPROTEC 5 7SJ86 (CP200) (All versions), SIPROTEC 5 7SJ86 (CP300) (All versions < V9.50), SIPROTEC 5 7SK82 (CP100) (All versions < V8.89), SIPROTEC 5 7SK82 (CP150) (All versions < V9.50), SIPROTEC 5 7SK85 (CP200) (All versions), SIPROTEC 5 7SK85 (CP300) (All versions < V9.50), SIPROTEC 5 7SL82 (CP100) (All versions < V8.90), SIPROTEC 5 7SL82 (CP150) (All versions < V9.50), SIPROTEC 5 7SL86 (CP200) (All versions), SIPROTEC 5 7SL86 (CP300) (All versions < V9.50), SIPROTEC 5 7SL87 (CP200) (All versions), SIPROTEC 5 7SL87 (CP300) (All versions < V9.50), SIPROTEC 5 7SS85 (CP200) (All versions), SIPROTEC 5 7SS85 (CP300) (All versions < V9.50), SIPROTEC 5 7ST85 (CP200) (All versions), SIPROTEC 5 7ST85 (CP300) (All versions < V9.64), SIPROTEC 5 7ST86 (CP300) (All versions < V9.64), SIPROTEC 5 7SX82 (CP150) (All versions < V9.50), SIPROTEC 5 7SX85 (CP300) (All versions < V9.50), SIPROTEC 5 7UM85 (CP300) (All versions < V9.50), SIPROTEC 5 7UT82 (CP100) (All versions < V8.90), SIPROTEC 5 7UT82 (CP150) (All versions < V9.50), SIPROTEC 5 7UT85 (CP200) (All versions), SIPROTEC 5 7UT85 (CP300) (All versions < V9.50), SIPROTEC 5 7UT86 (CP200) (All versions), SIPROTEC 5 7UT86 (CP300) (All versions < V9.50), SIPROTEC 5 7UT87 (CP200) (All versions), SIPROTEC 5 7UT87 (CP300) (All versions < V9.50), SIPROTEC 5 7VE85 (CP300) (All versions < V9.50), SIPROTEC 5 7VK87 (CP200) (All versions), SIPROTEC 5 7VK87 (CP300) (All versions < V9.50), SIPROTEC 5 7VU85 (CP300) (All versions < V9.50), SIPROTEC 5 Communication Module ETH-BA-2EL (Rev.1) (All versions installed on CP200 devices), SIPROTEC 5 Communication Module ETH-BA-2EL (Rev.1) (All versions < V9.50 installed on CP150 and CP300 devices), SIPROTEC 5 Communication Module ETH-BA-2EL (Rev.1) (All versions < V8.89 installed on CP100 devices), SIPROTEC 5 Communication Module ETH-BB-2FO (Rev. 1) (All versions installed on CP200 devices), SIPROTEC 5 Communication Module ETH-BB-2FO (Rev. 1) (All versions < V9.50 installed on CP150 and CP300 devices), SIPROTEC 5 Communication Module ETH-BB-2FO (Rev. 1) (All versions < V8.89 installed on CP100 devices), SIPROTEC 5 Communication Module ETH-BD-2FO (All versions < V9.50), SIPROTEC 5 Compact 7SX800 (CP050) (All versions < V9.50). Affected devices do not properly restrict secure client-initiated renegotiations within the SSL and TLS protocols. This could allow an attacker to create a denial of service condition on the ports 443/tcp and 4443/tcp for the duration of the attack.

Affected (CNA)

Vendor / productVersions
Siemens / SIPROTEC 5 6MD84 (CP300)affected 0 before V9.50
Siemens / SIPROTEC 5 6MD85 (CP200)affected 0 before *
Siemens / SIPROTEC 5 6MD85 (CP300)affected 0 before V9.50
Siemens / SIPROTEC 5 6MD86 (CP200)affected 0 before *
Siemens / SIPROTEC 5 6MD86 (CP300)affected 0 before V9.50
Siemens / SIPROTEC 5 6MD89 (CP300)affected 0 before V9.64
Siemens / SIPROTEC 5 6MU85 (CP300)affected 0 before V9.50
Siemens / SIPROTEC 5 7KE85 (CP200)affected 0 before *
Siemens / SIPROTEC 5 7KE85 (CP300)affected 0 before V9.64
Siemens / SIPROTEC 5 7SA82 (CP100)affected 0 before V8.90
Siemens / SIPROTEC 5 7SA82 (CP150)affected 0 before V9.50
Siemens / SIPROTEC 5 7SA84 (CP200)affected 0 before *
Siemens / SIPROTEC 5 7SA86 (CP200)affected 0 before *
Siemens / SIPROTEC 5 7SA86 (CP300)affected 0 before V9.50
Siemens / SIPROTEC 5 7SA87 (CP200)affected 0 before *
Siemens / SIPROTEC 5 7SA87 (CP300)affected 0 before V9.50
Siemens / SIPROTEC 5 7SD82 (CP100)affected 0 before V8.90
Siemens / SIPROTEC 5 7SD82 (CP150)affected 0 before V9.50
Siemens / SIPROTEC 5 7SD84 (CP200)affected 0 before *
Siemens / SIPROTEC 5 7SD86 (CP200)affected 0 before *
Siemens / SIPROTEC 5 7SD86 (CP300)affected 0 before V9.50
Siemens / SIPROTEC 5 7SD87 (CP200)affected 0 before *
Siemens / SIPROTEC 5 7SD87 (CP300)affected 0 before V9.50
Siemens / SIPROTEC 5 7SJ81 (CP100)affected 0 before V8.89
Siemens / SIPROTEC 5 7SJ81 (CP150)affected 0 before V9.50
Siemens / SIPROTEC 5 7SJ82 (CP100)affected 0 before V8.89
Siemens / SIPROTEC 5 7SJ82 (CP150)affected 0 before V9.50
Siemens / SIPROTEC 5 7SJ85 (CP200)affected 0 before *
Siemens / SIPROTEC 5 7SJ85 (CP300)affected 0 before V9.50
Siemens / SIPROTEC 5 7SJ86 (CP200)affected 0 before *
Siemens / SIPROTEC 5 7SJ86 (CP300)affected 0 before V9.50
Siemens / SIPROTEC 5 7SK82 (CP100)affected 0 before V8.89
Siemens / SIPROTEC 5 7SK82 (CP150)affected 0 before V9.50
Siemens / SIPROTEC 5 7SK85 (CP200)affected 0 before *
Siemens / SIPROTEC 5 7SK85 (CP300)affected 0 before V9.50
Siemens / SIPROTEC 5 7SL82 (CP100)affected 0 before V8.90
Siemens / SIPROTEC 5 7SL82 (CP150)affected 0 before V9.50
Siemens / SIPROTEC 5 7SL86 (CP200)affected 0 before *
Siemens / SIPROTEC 5 7SL86 (CP300)affected 0 before V9.50
Siemens / SIPROTEC 5 7SL87 (CP200)affected 0 before *
Siemens / SIPROTEC 5 7SL87 (CP300)affected 0 before V9.50
Siemens / SIPROTEC 5 7SS85 (CP200)affected 0 before *
Siemens / SIPROTEC 5 7SS85 (CP300)affected 0 before V9.50
Siemens / SIPROTEC 5 7ST85 (CP200)affected 0 before *
Siemens / SIPROTEC 5 7ST85 (CP300)affected 0 before V9.64
Siemens / SIPROTEC 5 7ST86 (CP300)affected 0 before V9.64
Siemens / SIPROTEC 5 7SX82 (CP150)affected 0 before V9.50
Siemens / SIPROTEC 5 7SX85 (CP300)affected 0 before V9.50
Siemens / SIPROTEC 5 7UM85 (CP300)affected 0 before V9.50
Siemens / SIPROTEC 5 7UT82 (CP100)affected 0 before V8.90
Siemens / SIPROTEC 5 7UT82 (CP150)affected 0 before V9.50
Siemens / SIPROTEC 5 7UT85 (CP200)affected 0 before *
Siemens / SIPROTEC 5 7UT85 (CP300)affected 0 before V9.50
Siemens / SIPROTEC 5 7UT86 (CP200)affected 0 before *
Siemens / SIPROTEC 5 7UT86 (CP300)affected 0 before V9.50
Siemens / SIPROTEC 5 7UT87 (CP200)affected 0 before *
Siemens / SIPROTEC 5 7UT87 (CP300)affected 0 before V9.50
Siemens / SIPROTEC 5 7VE85 (CP300)affected 0 before V9.50
Siemens / SIPROTEC 5 7VK87 (CP200)affected 0 before *
Siemens / SIPROTEC 5 7VK87 (CP300)affected 0 before V9.50
Siemens / SIPROTEC 5 7VU85 (CP300)affected 0 before V9.50
Siemens / SIPROTEC 5 Communication Module ETH-BA-2EL (Rev.1)affected 0 before *
Siemens / SIPROTEC 5 Communication Module ETH-BA-2EL (Rev.1)affected 0 before V9.50
Siemens / SIPROTEC 5 Communication Module ETH-BA-2EL (Rev.1)affected 0 before V8.89
Siemens / SIPROTEC 5 Communication Module ETH-BB-2FO (Rev. 1)affected 0 before *
Siemens / SIPROTEC 5 Communication Module ETH-BB-2FO (Rev. 1)affected 0 before V9.50
Siemens / SIPROTEC 5 Communication Module ETH-BB-2FO (Rev. 1)affected 0 before V8.89
Siemens / SIPROTEC 5 Communication Module ETH-BD-2FOaffected 0 before V9.50
Siemens / SIPROTEC 5 Compact 7SX800 (CP050)affected 0 before V9.50

CWE

CWE-400

References

ADP enrichment

CVE

No English description supplied.