Description (CNA)
A vulnerability has been identified in Mendix SAML (Mendix 7 compatible) (All versions >= V1.17.3 < V1.18.0), Mendix SAML (Mendix 7 compatible) (All versions >= V1.16.4 < V1.17.3), Mendix SAML (Mendix 8 compatible) (All versions >= V2.3.0 < V2.4.0), Mendix SAML (Mendix 8 compatible) (All versions >= V2.2.0 < V2.3.0), Mendix SAML (Mendix 9 latest compatible, New Track) (All versions >= V3.3.1 < V3.6.1), Mendix SAML (Mendix 9 latest compatible, New Track) (All versions >= V3.1.9 < V3.3.1), Mendix SAML (Mendix 9 latest compatible, Upgrade Track) (All versions >= V3.3.0 < V3.6.0), Mendix SAML (Mendix 9 latest compatible, Upgrade Track) (All versions >= V3.1.8 < V3.3.0), Mendix SAML (Mendix 9.12/9.18 compatible, New Track) (All versions >= V3.3.1 < V3.3.15), Mendix SAML (Mendix 9.12/9.18 compatible, Upgrade Track) (All versions >= V3.3.0 < V3.3.14), Mendix SAML (Mendix 9.6 compatible, New Track) (All versions >= V3.1.9 < V3.2.7), Mendix SAML (Mendix 9.6 compatible, Upgrade Track) (All versions >= V3.1.8 < V3.2.6). The affected versions of the module insufficiently verify the SAML assertions. This could allow unauthenticated remote attackers to bypass authentication and get access to the application. This CVE entry describes the incomplete fix for CVE-2023-25957 in a specific non default configuration.
Affected (CNA)
| Vendor / product | Versions |
|---|---|
| Siemens / Mendix SAML (Mendix 7 compatible) | affected All versions >= V1.17.3 < V1.18.0 |
| Siemens / Mendix SAML (Mendix 7 compatible) | affected All versions >= V1.16.4 < V1.17.3 |
| Siemens / Mendix SAML (Mendix 8 compatible) | affected All versions >= V2.3.0 < V2.4.0 |
| Siemens / Mendix SAML (Mendix 8 compatible) | affected All versions >= V2.2.0 < V2.3.0 |
| Siemens / Mendix SAML (Mendix 9 latest compatible, New Track) | affected All versions >= V3.3.1 < V3.6.1 |
| Siemens / Mendix SAML (Mendix 9 latest compatible, New Track) | affected All versions >= V3.1.9 < V3.3.1 |
| Siemens / Mendix SAML (Mendix 9 latest compatible, Upgrade Track) | affected All versions >= V3.3.0 < V3.6.0 |
| Siemens / Mendix SAML (Mendix 9 latest compatible, Upgrade Track) | affected All versions >= V3.1.8 < V3.3.0 |
| Siemens / Mendix SAML (Mendix 9.12/9.18 compatible, New Track) | affected All versions >= V3.3.1 < V3.3.15 |
| Siemens / Mendix SAML (Mendix 9.12/9.18 compatible, Upgrade Track) | affected All versions >= V3.3.0 < V3.3.14 |
| Siemens / Mendix SAML (Mendix 9.6 compatible, New Track) | affected All versions >= V3.1.9 < V3.2.7 |
| Siemens / Mendix SAML (Mendix 9.6 compatible, Upgrade Track) | affected All versions >= V3.1.8 < V3.2.6 |
CWE
CWE-303
References
ADP enrichment
No English description supplied.
No English description supplied.
No references supplied.