Description (CNA)
A vulnerability has been identified in SIMATIC MV540 H (All versions < V3.3.4), SIMATIC MV540 S (All versions < V3.3.4), SIMATIC MV550 H (All versions < V3.3.4), SIMATIC MV550 S (All versions < V3.3.4), SIMATIC MV560 U (All versions < V3.3.4), SIMATIC MV560 X (All versions < V3.3.4). Affected devices cannot properly process specially crafted IP packets sent to the devices. This could allow an unauthenticated remote attacker to cause a denial of service condition. The affected devices must be restarted manually.
Affected (CNA)
| Vendor / product | Versions |
|---|---|
| Siemens / SIMATIC MV540 H | affected All versions < V3.3.4 |
| Siemens / SIMATIC MV540 S | affected All versions < V3.3.4 |
| Siemens / SIMATIC MV550 H | affected All versions < V3.3.4 |
| Siemens / SIMATIC MV550 S | affected All versions < V3.3.4 |
| Siemens / SIMATIC MV560 U | affected All versions < V3.3.4 |
| Siemens / SIMATIC MV560 X | affected All versions < V3.3.4 |
CWE
CWE-400
References
ADP enrichment
No English description supplied.
No English description supplied.
No references supplied.