Description (CNA)
1E Client installer can perform arbitrary file deletion on protected files. A non-privileged user could provide a symbolic link or Windows junction to point to a protected directory in the installer that the 1E Client would then clear on service startup. A hotfix is available from the 1E support portal that forces the 1E Client to check for a symbolic link or junction and if it finds one refuses to use that path and instead creates a path involving a random GUID. for v8.1 use hotfix Q23097 for v8.4 use hotfix Q23105 for v9.0 use hotfix Q23115 for SaaS customers, use 1EClient v23.7 plus hotfix Q23121
Affected (CNA)
| Vendor / product | Versions |
|---|---|
| 1E / 1E Client | affected 0 before 8.1.2.62; affected 0 before 8.4.1.159; affected 0 before 9.0.1.88; affected 0 before 23.7.1.151 |
CWE
CWE-59
References
ADP enrichment
No English description supplied.
No English description supplied.
No references supplied.