Description (CNA)
A vulnerability, which was classified as critical, was found in Tenda AC7 15.03.06.44. Affected is the function formQuickIndex of the file /goform/QuickIndex. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-257934 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Affected (CNA)
| Vendor / product | Versions |
|---|---|
| Tenda / AC7 | affected 15.03.06.44 |
CWE
CWE-121
References
- https://vuldb.com/?id.257934
- https://vuldb.com/?ctiid.257934
- https://vuldb.com/?submit.300354
- https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/formQuickIndex.md
ADP enrichment
No English description supplied.
No references supplied.
No English description supplied.