Description (CNA)
A vulnerability has been identified in RUGGEDCOM RMC30 (All versions < V4.3.10), RUGGEDCOM RMC30NC (All versions < V4.3.10), RUGGEDCOM RP110 (All versions < V4.3.10), RUGGEDCOM RP110NC (All versions < V4.3.10), RUGGEDCOM RS400 (All versions < V4.3.10), RUGGEDCOM RS400NC (All versions < V4.3.10), RUGGEDCOM RS401 (All versions < V4.3.10), RUGGEDCOM RS401NC (All versions < V4.3.10), RUGGEDCOM RS416 (All versions < V4.3.10), RUGGEDCOM RS416NC (All versions < V4.3.10), RUGGEDCOM RS416NCv2 V4.X (All versions < V4.3.10), RUGGEDCOM RS416NCv2 V5.X (All versions < V5.9.0), RUGGEDCOM RS416P (All versions < V4.3.10), RUGGEDCOM RS416PNC (All versions < V4.3.10), RUGGEDCOM RS416PNCv2 V4.X (All versions < V4.3.10), RUGGEDCOM RS416PNCv2 V5.X (All versions < V5.9.0), RUGGEDCOM RS416Pv2 V4.X (All versions < V4.3.10), RUGGEDCOM RS416Pv2 V5.X (All versions < V5.9.0), RUGGEDCOM RS416v2 V4.X (All versions < V4.3.10), RUGGEDCOM RS416v2 V5.X (All versions < V5.9.0), RUGGEDCOM RS910 (All versions < V4.3.10), RUGGEDCOM RS910L (All versions), RUGGEDCOM RS910LNC (All versions), RUGGEDCOM RS910NC (All versions < V4.3.10), RUGGEDCOM RS910W (All versions < V4.3.10), RUGGEDCOM RS920L (All versions), RUGGEDCOM RS920LNC (All versions), RUGGEDCOM RS920W (All versions). In some configurations the affected products wrongly enable the Modbus service in non-managed VLANS. Only serial devices are affected by this vulnerability.
Affected (CNA)
| Vendor / product | Versions |
|---|---|
| Siemens / RUGGEDCOM RMC30 | affected 0 before V4.3.10 |
| Siemens / RUGGEDCOM RMC30NC | affected 0 before V4.3.10 |
| Siemens / RUGGEDCOM RP110 | affected 0 before V4.3.10 |
| Siemens / RUGGEDCOM RP110NC | affected 0 before V4.3.10 |
| Siemens / RUGGEDCOM RS400 | affected 0 before V4.3.10 |
| Siemens / RUGGEDCOM RS400NC | affected 0 before V4.3.10 |
| Siemens / RUGGEDCOM RS401 | affected 0 before V4.3.10 |
| Siemens / RUGGEDCOM RS401NC | affected 0 before V4.3.10 |
| Siemens / RUGGEDCOM RS416 | affected 0 before V4.3.10 |
| Siemens / RUGGEDCOM RS416NC | affected 0 before V4.3.10 |
| Siemens / RUGGEDCOM RS416NCv2 V4.X | affected 0 before V4.3.10 |
| Siemens / RUGGEDCOM RS416NCv2 V5.X | affected 0 before V5.9.0 |
| Siemens / RUGGEDCOM RS416P | affected 0 before V4.3.10 |
| Siemens / RUGGEDCOM RS416PNC | affected 0 before V4.3.10 |
| Siemens / RUGGEDCOM RS416PNCv2 V4.X | affected 0 before V4.3.10 |
| Siemens / RUGGEDCOM RS416PNCv2 V5.X | affected 0 before V5.9.0 |
| Siemens / RUGGEDCOM RS416Pv2 V4.X | affected 0 before V4.3.10 |
| Siemens / RUGGEDCOM RS416Pv2 V5.X | affected 0 before V5.9.0 |
| Siemens / RUGGEDCOM RS416v2 V4.X | affected 0 before V4.3.10 |
| Siemens / RUGGEDCOM RS416v2 V5.X | affected 0 before V5.9.0 |
| Siemens / RUGGEDCOM RS910 | affected 0 before V4.3.10 |
| Siemens / RUGGEDCOM RS910L | affected 0 before * |
| Siemens / RUGGEDCOM RS910LNC | affected 0 before * |
| Siemens / RUGGEDCOM RS910NC | affected 0 before V4.3.10 |
| Siemens / RUGGEDCOM RS910W | affected 0 before V4.3.10 |
| Siemens / RUGGEDCOM RS920L | affected 0 before * |
| Siemens / RUGGEDCOM RS920LNC | affected 0 before * |
| Siemens / RUGGEDCOM RS920W | affected 0 before * |
CWE
CWE-497
References
ADP enrichment
No English description supplied.
No references supplied.
No English description supplied.