Description (CNA)
A vulnerability has been identified in Teamcenter Visualization V14.2 (All versions < V14.2.0.14), Teamcenter Visualization V14.3 (All versions < V14.3.0.12), Teamcenter Visualization V2312 (All versions < V2312.0008), Teamcenter Visualization V2406 (All versions < V2406.0005), Tecnomatix Plant Simulation V2302 (All versions < V2302.0018), Tecnomatix Plant Simulation V2404 (All versions < V2404.0007). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-24237)
Affected (CNA)
| Vendor / product | Versions |
|---|---|
| Siemens / Teamcenter Visualization V14.2 | affected 0 before V14.2.0.14 |
| Siemens / Teamcenter Visualization V14.3 | affected 0 before V14.3.0.12 |
| Siemens / Teamcenter Visualization V2312 | affected 0 before V2312.0008 |
| Siemens / Teamcenter Visualization V2406 | affected 0 before V2406.0005 |
| Siemens / Tecnomatix Plant Simulation V2302 | affected 0 before V2302.0018 |
| Siemens / Tecnomatix Plant Simulation V2404 | affected 0 before V2404.0007 |
CWE
CWE-125
References
- https://cert-portal.siemens.com/productcert/html/ssa-824503.html
- https://cert-portal.siemens.com/productcert/html/ssa-645131.html
ADP enrichment
No English description supplied.
No references supplied.