Description (CNA)
An exposure of sensitive information vulnerability exists in the Rockwell Automation FactoryTalk® System Service. A malicious user could exploit this vulnerability by starting a back-up or restore process, which temporarily exposes private keys, passwords, pre-shared keys, and database folders when they are temporarily copied to an interim folder. This vulnerability is due to the lack of explicit permissions set on the backup folder. If private keys are obtained by a malicious user, they could impersonate resources on the secured network.
Affected (CNA)
| Vendor / product | Versions |
|---|---|
| Rockwell Automation / FactoryTalk® System Services (installed via FTPM) | affected v6.40 |
| Rockwell Automation / FactoryTalk® Policy Manager (FTPM) | affected v6.40 |
CWE
CWE-269
References
ADP enrichment
No English description supplied.
No references supplied.