Description (CNA)
Magnet Forensics AXIOM Command Injection Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of Magnet Forensics AXIOM. User interaction is required to exploit this vulnerability in that the target must acquire data from a malicious mobile device. The specific flaw exists within the Android device image acquisition functionality. The issue results from the lack of proper validation of a user-supplied string before using it to execute a system call. An attacker can leverage this vulnerability to execute code in the context of the current user. Was ZDI-CAN-23964.
Affected (CNA)
| Vendor / product | Versions |
|---|---|
| Magnet Forensics / AXIOM | affected 8.0.0.39753 |
CWE
CWE-78
References
- https://www.zerodayinitiative.com/advisories/ZDI-24-1129/
- https://docs.magnetforensics.com/docs/axiom/release_notes.html
ADP enrichment
No English description supplied.