Description (CNA)
A vulnerability has been identified in RUGGEDCOM RMC8388 V5.X (All versions < V5.10.0), RUGGEDCOM RMC8388NC V5.X (All versions < V5.10.0), RUGGEDCOM RS416NCv2 V5.X (All versions < V5.10.0), RUGGEDCOM RS416PNCv2 V5.X (All versions < V5.10.0), RUGGEDCOM RS416Pv2 V5.X (All versions < V5.10.0), RUGGEDCOM RS416v2 V5.X (All versions < V5.10.0), RUGGEDCOM RS900 (32M) V5.X (All versions < V5.10.0), RUGGEDCOM RS900G (32M) V5.X (All versions < V5.10.0), RUGGEDCOM RS900GNC(32M) V5.X (All versions < V5.10.0), RUGGEDCOM RS900NC(32M) V5.X (All versions < V5.10.0), RUGGEDCOM RSG2100 (32M) V5.X (All versions < V5.10.0), RUGGEDCOM RSG2100NC(32M) V5.X (All versions < V5.10.0), RUGGEDCOM RSG2100P (32M) V5.X (All versions < V5.10.0), RUGGEDCOM RSG2100PNC (32M) V5.X (All versions < V5.10.0), RUGGEDCOM RSG2288 V5.X (All versions < V5.10.0), RUGGEDCOM RSG2288NC V5.X (All versions < V5.10.0), RUGGEDCOM RSG2300 V5.X (All versions < V5.10.0), RUGGEDCOM RSG2300NC V5.X (All versions < V5.10.0), RUGGEDCOM RSG2300P V5.X (All versions < V5.10.0), RUGGEDCOM RSG2300PNC V5.X (All versions < V5.10.0), RUGGEDCOM RSG2488 V5.X (All versions < V5.10.0), RUGGEDCOM RSG2488NC V5.X (All versions < V5.10.0), RUGGEDCOM RSG907R (All versions < V5.10.0), RUGGEDCOM RSG908C (All versions < V5.10.0), RUGGEDCOM RSG909R (All versions < V5.10.0), RUGGEDCOM RSG910C (All versions < V5.10.0), RUGGEDCOM RSG920P V5.X (All versions < V5.10.0), RUGGEDCOM RSG920PNC V5.X (All versions < V5.10.0), RUGGEDCOM RSL910 (All versions < V5.10.0), RUGGEDCOM RSL910NC (All versions < V5.10.0), RUGGEDCOM RST2228 (All versions < V5.10.0), RUGGEDCOM RST2228P (All versions < V5.10.0), RUGGEDCOM RST916C (All versions < V5.10.0), RUGGEDCOM RST916P (All versions < V5.10.0). The affected products do not properly enforce interface access restrictions when changing from management to non-management interface configurations until a system reboot occurs, despite configuration being saved. This could allow an attacker with network access and credentials to gain access to device through non-management and maintain SSH access to the device until reboot.
Affected (CNA)
| Vendor / product | Versions |
|---|---|
| Siemens / RUGGEDCOM RMC8388 V5.X | affected 0 before V5.10.0 |
| Siemens / RUGGEDCOM RMC8388NC V5.X | affected 0 before V5.10.0 |
| Siemens / RUGGEDCOM RS416NCv2 V5.X | affected 0 before V5.10.0 |
| Siemens / RUGGEDCOM RS416PNCv2 V5.X | affected 0 before V5.10.0 |
| Siemens / RUGGEDCOM RS416Pv2 V5.X | affected 0 before V5.10.0 |
| Siemens / RUGGEDCOM RS416v2 V5.X | affected 0 before V5.10.0 |
| Siemens / RUGGEDCOM RS900 (32M) V5.X | affected 0 before V5.10.0 |
| Siemens / RUGGEDCOM RS900G (32M) V5.X | affected 0 before V5.10.0 |
| Siemens / RUGGEDCOM RS900GNC(32M) V5.X | affected 0 before V5.10.0 |
| Siemens / RUGGEDCOM RS900NC(32M) V5.X | affected 0 before V5.10.0 |
| Siemens / RUGGEDCOM RSG2100 (32M) V5.X | affected 0 before V5.10.0 |
| Siemens / RUGGEDCOM RSG2100NC(32M) V5.X | affected 0 before V5.10.0 |
| Siemens / RUGGEDCOM RSG2100P (32M) V5.X | affected 0 before V5.10.0 |
| Siemens / RUGGEDCOM RSG2100PNC (32M) V5.X | affected 0 before V5.10.0 |
| Siemens / RUGGEDCOM RSG2288 V5.X | affected 0 before V5.10.0 |
| Siemens / RUGGEDCOM RSG2288NC V5.X | affected 0 before V5.10.0 |
| Siemens / RUGGEDCOM RSG2300 V5.X | affected 0 before V5.10.0 |
| Siemens / RUGGEDCOM RSG2300NC V5.X | affected 0 before V5.10.0 |
| Siemens / RUGGEDCOM RSG2300P V5.X | affected 0 before V5.10.0 |
| Siemens / RUGGEDCOM RSG2300PNC V5.X | affected 0 before V5.10.0 |
| Siemens / RUGGEDCOM RSG2488 V5.X | affected 0 before V5.10.0 |
| Siemens / RUGGEDCOM RSG2488NC V5.X | affected 0 before V5.10.0 |
| Siemens / RUGGEDCOM RSG907R | affected 0 before V5.10.0 |
| Siemens / RUGGEDCOM RSG908C | affected 0 before V5.10.0 |
| Siemens / RUGGEDCOM RSG909R | affected 0 before V5.10.0 |
| Siemens / RUGGEDCOM RSG910C | affected 0 before V5.10.0 |
| Siemens / RUGGEDCOM RSG920P V5.X | affected 0 before V5.10.0 |
| Siemens / RUGGEDCOM RSG920PNC V5.X | affected 0 before V5.10.0 |
| Siemens / RUGGEDCOM RSL910 | affected 0 before V5.10.0 |
| Siemens / RUGGEDCOM RSL910NC | affected 0 before V5.10.0 |
| Siemens / RUGGEDCOM RST2228 | affected 0 before V5.10.0 |
| Siemens / RUGGEDCOM RST2228P | affected 0 before V5.10.0 |
| Siemens / RUGGEDCOM RST916C | affected 0 before V5.10.0 |
| Siemens / RUGGEDCOM RST916P | affected 0 before V5.10.0 |
CWE
CWE-693
References
ADP enrichment
No English description supplied.
No references supplied.