← CVE Intelligence

CVE-2025-41751

Reflected XSS vulnerability in pxc_portCntr.php PUBLISHED

Description (CNA)

An XSS vulnerability in pxc_portCntr.php can be used by an unauthenticated remote attacker to trick an authenticated user to click on the link provided by the attacker in order to change parameters available via web based management (WBM). The vulnerability does not provide access to system-level resources such as operating system internals or privileged functions. Access is limited to device configuration parameters that are available in the context of the web application. The session cookie is secured by the httpOnly Flag. Therefore an attacker is not able to take over the session of an authenticated user.

Affected (CNA)

Vendor / productVersions
Phoenix Contact / FL SWITCH 2005affected 0.0.0 before 3.50
Phoenix Contact / FL SWITCH 2008affected 0.0.0 before 3.50
Phoenix Contact / FL SWITCH 2016affected 0.0.0 before 3.50
Phoenix Contact / FL SWITCH 2105affected 0.0.0 before 3.50
Phoenix Contact / FL SWITCH 2108affected 0.0.0 before 3.50
Phoenix Contact / FL SWITCH 2116affected 0.0.0 before 3.50
Phoenix Contact / FL SWITCH 2204-2TC-2SFXaffected 0.0.0 before 3.50
Phoenix Contact / FL SWITCH 2205affected 0.0.0 before 3.50
Phoenix Contact / FL SWITCH 2206-2FXaffected 0.0.0 before 3.50
Phoenix Contact / FL SWITCH 2206-2FX SMaffected 0.0.0 before 3.50
Phoenix Contact / FL SWITCH 2206-2FX SM STaffected 0.0.0 before 3.50
Phoenix Contact / FL SWITCH 2206-2FX STaffected 0.0.0 before 3.50
Phoenix Contact / FL SWITCH 2206-2SFXaffected 0.0.0 before 3.50
Phoenix Contact / FL SWITCH 2206-2SFX PNaffected 0.0.0 before 3.50
Phoenix Contact / FL SWITCH 2206C-2FXaffected 0.0.0 before 3.50
Phoenix Contact / FL SWITCH 2207-FXaffected 0.0.0 before 3.50
Phoenix Contact / FL SWITCH 2207-FX SMaffected 0.0.0 before 3.50
Phoenix Contact / FL SWITCH 2208affected 0.0.0 before 3.50
Phoenix Contact / FL SWITCH 2208 PNaffected 0.0.0 before 3.50
Phoenix Contact / FL SWITCH 2208Caffected 0.0.0 before 3.50
Phoenix Contact / FL SWITCH 2212-2TC-2SFXaffected 0.0.0 before 3.50
Phoenix Contact / FL SWITCH 2214-2FXaffected 0.0.0 before 3.50
Phoenix Contact / FL SWITCH 2214-2FX SMaffected 0.0.0 before 3.50
Phoenix Contact / FL SWITCH 2214-2SFXaffected 0.0.0 before 3.50
Phoenix Contact / FL SWITCH 2214-2SFX PNaffected 0.0.0 before 3.50
Phoenix Contact / FL SWITCH 2216affected 0.0.0 before 3.50
Phoenix Contact / FL SWITCH 2216 PNaffected 0.0.0 before 3.50
Phoenix Contact / FL SWITCH 2304-2GC-2SFPaffected 0.0.0 before 3.50
Phoenix Contact / FL SWITCH 2306-2SFPaffected 0.0.0 before 3.50
Phoenix Contact / FL SWITCH 2306-2SFP PNaffected 0.0.0 before 3.50
Phoenix Contact / FL SWITCH 2308affected 0.0.0 before 3.50
Phoenix Contact / FL SWITCH 2308 PNaffected 0.0.0 before 3.50
Phoenix Contact / FL SWITCH 2312-2GC-2SFPaffected 0.0.0 before 3.50
Phoenix Contact / FL SWITCH 2314-2SFPaffected 0.0.0 before 3.50
Phoenix Contact / FL SWITCH 2314-2SFP PNaffected 0.0.0 before 3.50
Phoenix Contact / FL SWITCH 2316affected 0.0.0 before 3.50
Phoenix Contact / FL SWITCH 2316 PNaffected 0.0.0 before 3.50
Phoenix Contact / FL SWITCH 2404-2TC-2SFXaffected 0.0.0 before 3.50
Phoenix Contact / FL SWITCH 2406-2SFXaffected 0.0.0 before 3.50
Phoenix Contact / FL SWITCH 2406-2SFX PNaffected 0.0.0 before 3.50
Phoenix Contact / FL SWITCH 2408affected 0.0.0 before 3.50
Phoenix Contact / FL SWITCH 2408 PNaffected 0.0.0 before 3.50
Phoenix Contact / FL SWITCH 2412-2TC-2SFXaffected 0.0.0 before 3.50
Phoenix Contact / FL SWITCH 2414-2SFXaffected 0.0.0 before 3.50
Phoenix Contact / FL SWITCH 2414-2SFX PNaffected 0.0.0 before 3.50
Phoenix Contact / FL SWITCH 2416affected 0.0.0 before 3.50
Phoenix Contact / FL SWITCH 2416 PNaffected 0.0.0 before 3.50
Phoenix Contact / FL SWITCH 2504-2GC-2SFPaffected 0.0.0 before 3.50
Phoenix Contact / FL SWITCH 2506-2SFPaffected 0.0.0 before 3.50
Phoenix Contact / FL SWITCH 2506-2SFP PNaffected 0.0.0 before 3.50
Phoenix Contact / FL SWITCH 2508affected 0.0.0 before 3.50
Phoenix Contact / FL SWITCH 2508 PNaffected 0.0.0 before 3.50
Phoenix Contact / FL SWITCH 2512-2GC-2SFPaffected 0.0.0 before 3.50
Phoenix Contact / FL SWITCH 2514-2SFPaffected 0.0.0 before 3.50
Phoenix Contact / FL SWITCH 2514-2SFP PNaffected 0.0.0 before 3.50
Phoenix Contact / FL SWITCH 2516affected 0.0.0 before 3.50
Phoenix Contact / FL SWITCH 2516 PNaffected 0.0.0 before 3.50
Phoenix Contact / FL SWITCH 2608affected 0.0.0 before 3.50
Phoenix Contact / FL SWITCH 2608 PNaffected 0.0.0 before 3.50
Phoenix Contact / FL SWITCH 2708affected 0.0.0 before 3.50
Phoenix Contact / FL SWITCH 2708 PNaffected 0.0.0 before 3.50
Phoenix Contact / FL SWITCH 2303-8SP1affected 0.0.0 before 3.50
Phoenix Contact / FL NAT 2008affected 0.0.0 before 3.50
Phoenix Contact / FL NAT 2208affected 0.0.0 before 3.50
Phoenix Contact / FL NAT 2304-2GC-2SFPaffected 0.0.0 before 3.50
Phoenix Contact / FL SWITCH 2008Faffected 0.0.0 before 3.50
Phoenix Contact / FL SWITCH 2316/K1affected 0.0.0 before 3.50
Phoenix Contact / FL SWITCH 2506-2SFP/K1affected 0.0.0 before 3.50
Phoenix Contact / FL SWITCH 2508/K1affected 0.0.0 before 3.50

CWE

CWE-79

References

ADP enrichment

CISA-ADP

No English description supplied.

No references supplied.