Description (CNA)
AGL agl-service-can-low-level thru 17.1.12 contains a heap buffer over-read in the isotp-c library. In isotp_continue_receive (receive.c:87-89), the payload_length for a Single Frame is extracted from a 4-bit nibble in the CAN frame data, yielding values 0-15. However, a standard CAN frame is only 8 bytes, with payload starting at data[1] (7 bytes available). When payload_length exceeds the available data (e.g., nibble=15 but only 7 payload bytes exist), memcpy(message.payload, &data[1], payload_length) reads up to 8 bytes past the end of the data buffer.
Affected (CNA)
| Vendor / product | Versions |
|---|---|
| n/a / n/a | affected n/a |
CWE
No CWE identifiers supplied.
References
- https://gerrit.automotivelinux.org/gerrit/apps/agl-service-can-low-level