Description (CNA)
In the Linux kernel, the following vulnerability has been resolved: iommu/amd: Fix ineffective error check in nested domain allocation amd_iommu_pdom_id_alloc() returns an int: a domain ID on success, or the negative errno from ida_alloc_range() when the ID space is exhausted or memory is short. amd_iommu_alloc_domain_nested() stores that return value in gdom_info->hdom_id, which is a u32, and only then tests it: gdom_info->hdom_id = amd_iommu_pdom_id_alloc(); if (gdom_info->hdom_id <= 0) { The assignment discards the sign, so -ENOSPC becomes 0xffffffe4 and the test never fires. The nested domain is then set up with a host domain ID that was never allocated, instead of the allocation failing with -ENOSPC. Keep the value in an int, test it there, and store it only once it is known to be valid, which is what the other amd_iommu_pdom_id_alloc() callers already do.
Affected (CNA)
| Vendor / product | Versions |
|---|---|
| Linux / Linux | affected 757d2b1fdf5b7d6eead5963a49b5780617987ab8 before 80c231f5577229d1e90a1e312b3095f9502f8625; affected 757d2b1fdf5b7d6eead5963a49b5780617987ab8 before fa5c0827f0b7bac6d0a188f10118151769ae68fd |
| Linux / Linux | affected 7.0; unaffected 0 before 7.0; unaffected 7.2.7 through 7.2.*; unaffected 7.3 through * |
CWE