← CVE Intelligence

CVE-2021-31344

Siemens / Capital Embedded AR Classic 431-422 PUBLISHED

Description (CNA)

A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions < V2303), PLUSCONTROL 1st Gen (All versions), SIMOTICS CONNECT 400 (All versions < V0.5.0.0), SIMOTICS CONNECT 400 (All versions < V1.0.0.0). ICMP echo packets with fake IP options allow sending ICMP echo reply messages to arbitrary hosts on the network. (FSMD-2021-0004)

Affected (CNA)

Vendor / productVersions
Siemens / Capital Embedded AR Classic 431-422affected 0 before *
Siemens / Capital Embedded AR Classic R20-11affected 0 before V2303
Siemens / PLUSCONTROL 1st Genaffected All versions
Siemens / SIMOTICS CONNECT 400affected All versions < V0.5.0.0
Siemens / SIMOTICS CONNECT 400affected All versions < V1.0.0.0

CWE

CWE-843

References

ADP enrichment

CVE