Description (CNA)
A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions < V2303), PLUSCONTROL 1st Gen (All versions), SIMOTICS CONNECT 400 (All versions < V0.5.0.0), SIMOTICS CONNECT 400 (All versions < V1.0.0.0). The total length of an ICMP payload (set in the IP header) is unchecked. This may lead to various side effects, including Information Leak and Denial-of-Service conditions, depending on the network buffer organization in memory. (FSMD-2021-0007)
Affected (CNA)
| Vendor / product | Versions |
|---|---|
| Siemens / Capital Embedded AR Classic 431-422 | affected 0 before * |
| Siemens / Capital Embedded AR Classic R20-11 | affected 0 before V2303 |
| Siemens / PLUSCONTROL 1st Gen | affected All versions |
| Siemens / SIMOTICS CONNECT 400 | affected All versions < V0.5.0.0 |
| Siemens / SIMOTICS CONNECT 400 | affected All versions < V1.0.0.0 |
CWE
CWE-1284
References
- https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf
- https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf
- https://cert-portal.siemens.com/productcert/pdf/ssa-620288.pdf
- https://cert-portal.siemens.com/productcert/pdf/ssa-845392.pdf
- https://cert-portal.siemens.com/productcert/pdf/ssa-223353.pdf
- https://cert-portal.siemens.com/productcert/html/ssa-114589.html
- https://cert-portal.siemens.com/productcert/html/ssa-044112.html
- https://cert-portal.siemens.com/productcert/html/ssa-620288.html
- https://cert-portal.siemens.com/productcert/html/ssa-845392.html
- https://cert-portal.siemens.com/productcert/html/ssa-223353.html
ADP enrichment
No English description supplied.
- https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf
- https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf
- https://cert-portal.siemens.com/productcert/pdf/ssa-620288.pdf
- https://cert-portal.siemens.com/productcert/pdf/ssa-845392.pdf
- https://cert-portal.siemens.com/productcert/pdf/ssa-223353.pdf