Description (CNA)
The Ruckus vRIoT IoT Controller firmware versions prior to 3.0.0.0 (GA) expose a command execution service on TCP port 2004 running with root privileges. Authentication to this service relies on a hardcoded Time-based One-Time Password (TOTP) secret and an embedded static token. An attacker who extracts these credentials from the appliance or a compromised device can generate valid authentication tokens and execute arbitrary OS commands with root privileges, resulting in complete system compromise.
Affected (CNA)
| Vendor / product | Versions |
|---|---|
| RUCKUS Networks / vRIoT IoT Controller | affected 2.3.0.0 (GA) before 3.0.0.0 (GA); affected 2.3.1.0 (MR) before 3.0.0.0 (GA); affected 2.4.0.0 (GA) before 3.0.0.0 (GA) |
CWE
CWE-306, CWE-798
References
- https://support.ruckuswireless.com/security_bulletins/336
- https://www.vulncheck.com/advisories/ruckus-vriot-iot-controller-hardcoded-tokens-rce
ADP enrichment
No English description supplied.