← CVE Intelligence

CVE-2025-69426

Ruckus vRIoT IoT Controller < 3.0.0.0 Hardcoded SSH Credentials RCE PUBLISHED

Description (CNA)

The Ruckus vRIoT IoT Controller firmware versions prior to 3.0.0.0 (GA) contain hardcoded credentials for an operating system user account within an initialization script. The SSH service is network-accessible without IP-based restrictions. Although the configuration disables SCP and pseudo-TTY allocation, an attacker can authenticate using the hardcoded credentials and establish SSH local port forwarding to access the Docker socket. By mounting the host filesystem via Docker, an attacker can escape the container and execute arbitrary OS commands as root on the underlying vRIoT controller, resulting in complete system compromise.

Affected (CNA)

Vendor / productVersions
RUCKUS Networks / vRIoT IOT Controlleraffected 2.3.0.0 (GA) before 3.0.0.0 (GA); affected 2.3.1.0 (MR) before 3.0.0.0 (GA); affected 2.4.0.0 (GA) before 3.0.0.0 (GA)

CWE

CWE-732, CWE-798

References

ADP enrichment

CISA-ADP

No English description supplied.